Siehe Details auf eBay

Tattoo Entfernung 1064 & Sommersprossen Augenbrauen Pigment Entferner

EUR 2.632,97 oder Preisvorschlag Unsold, Kostenloser Versand, 1 Monat Rücknahmen

Verkäufer: modecathy (78.256) 98.1%, Artikelstandort: shanghai, Versand nach: DE, Artikelnummer: 123114718195 Description Specification: 10.4" color touch screen Cooling condition: wind system+closed circulating+cooling system type: Q-switch Nd: YAG With RED target light to aim on the skin The pulse energy: 0~1000mJ Pulse width: 6ms Laser wavelength: 1064nm / 532nm/BD-LS Recurrence rate: 1, 2, 3, 4, 5, 6Hz Power input: 110v~220v Power: 300W Plug:EU,US Application: The system gem-adjusting Q switch can effectively cure the mixed pigments by pigment precipitation of extraneous source with pathological pigment change of endogenous source, inclusive of erroneous dark eyebrow-embroidery, lip-embroidery, lip-soak, eye line-embroidery, lip-line, tattoo (inclusive of tattoo by extraneous wounds), pigment precipitation by sensitive source, freckle on female's face (male's), coffee spot, old age spot, black mole, and birthmark in black, blue, purple, brown, red and etc. Opeartion course for different illness case as follows: Opeartion s Opeartion course required ( cure times) Opeartion course interval Remark (requirements in surgery) eyebrow-embroidery(eyeliner grain) 1 –2 times 30-60 days Eyebrow blow, eyeball protection Eyebrow-embroidery ( eyeliner embroidery) 1-3 times 45-60 days Eyebrow blow, eyeball protection Lip line (red dyed lip) 1-3 times 15-45 days Use 532 filter Tattoo(caused by extraneous wounds) 1-4 times 30-60 days Blood infiltration will be fine on wounds Freckle, age spot 1-4 times 15-30 days Blood infiltration will be fine on wounds Birthmark, nevus/mole 3-7 times 45-90 days Must have Blood infiltration . (1)Opeartion for tattoo in eyebrow Customer could not open eyes during Opeartion , operator should adjust energy according to depth of tattoo color, hold the handle and move it to Opeartion area slowly to make customer feel acceptable in mentally. Right now, the speed of flash could be set 3HZ, keep head of the handle a two-finger distance to Opeartion area, start Opeartion from head of eyebrow to end of eyebrow. It is needed to treat again in 5-10 minutes if the color of tattoo re-appear. (2)Remove eye line The speed of flashes could be set 4-5HZ,adjust the energy of light to minimum energy, keep a one-finger distance between head of handle and Opeartion tment area. Operator should strictly protect customers’ eyes with panel for eyelid or medical pledget (panel for eyelid)of 1cm depth. Opeartion should be started from down eye line, customer should deeply close eyes and keep eyeball up-sight inside. Operator should press the pledget (panel for eyelid) with forefinger and push up eyelid, peel down eyelid with middle finger to bare the eye line, treat it with flashes of 4-5Hz. Then, treat up eye line. Also customer should close eyes and keep eyeball down-sight inside. Operator should press the pledget (panel for eyelid) with middle finger and push eyelid down, push eyelid up with forefinger to bare the eye line, treat it with flashes of 4-5Hz. (3)Remove lip line The speed of flashes could be set 5Hz,keep a 3/4 finger distance between head of handle and Opeartion area. It is better to remove black, coffee, deep, red and brown lip line with 1064 head at first time and then, treat again with 532 head. Notice: All tattoos in lip should be treated in 6 months after making. OR removal Opeartion will fail. It should have 45-60 days interval to continue next Opeartion until remove all. (4)Remove tattoo The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for Opeartion until Opeartion area seeps a little blood. It should have 45-90 days interval to continue next Opeartion until remove all. (5)Remove spot and nevus The speed of flashes could be set 3Hz/5Hz.Keep 3-4 fingers distance between head of handle and Opeartion area. It is better to use high energy for Opeartion until Opeartion area seeps a little blood. It is advised to use 1064 head for normal spot and nevus Opeartion , but for deep color spot and nevus, it is better to use 532 head for Opeartion . It should have a 15-30days interval to continue next Opeartion until remove all. (6)Remove birthmark The speed of flashes could be set 3Hz/5Hz.It is better to use high energy for Opeartion until treatOpeartion ment area seeps a little blood. It is advised to use 1064 head for birthmark Opeartion , but for red and deep color birthmark, it is better to use 532 head for Opeartion . It should have 45-90 days interval to continue Packing Listing 1 × Main Unit 1 x Handpiece 2 x Tips (1064nm~532nm), 1x BD-LS 1 × Water funnel 1 × Package box 1 × Foot touch 1 × Protective goggle 1 × Power line SKU:HYQ8041 Preview: Thank you for your purchase Problems? You can follow below process to chontact us. There is a time zone difference,but we will do our best to quickly response to your questions: Shipping - Handling time :48 hours - Standard to USA :about 7-14 working days(ePacket) -Economy to USA:about 20-35 working days(NO tracking under $5) - Economy Int'l Shipping:20-35 working days(NO tracking under $20) -Standard Int'l Shipping:20-35 working days(With tracking) -But like Russia,and some South Ameria country maybe need 2-3 weeks more. Please make sure your address in ebay is correct. we will only follow your address listed in the ebay orders for the shipment. Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer's responsibility. Payments We accepts Paypal only If you have any questions about the payment,please contact us through eBay message. Import Duties In case some duty is due Upon delivery, it is your responsibility to meet that expense and this may cause delays to delivery schedule and you may have to pickup goods at the customs office. Terms & Conditions By bidding on this item,the Buyer agrees to all of the terms and conditions as outlined in this listing .please ensure to read and agree to All eBay terms and Conditions before bidding. All pictures are for illustration purpose only and Colours may vary slightly. Our store obeys all eBay Rules and Policies. Returns Policy To Return an item you must contact us and take photos of your item to clearly show any damage or unusual aspects of it. Approved returns will be subject to inspection on arrival. Items must be returned in original condition with all original packaging. All shipping and handing charges are non-refundable Return delivery costs are the responsibility of the buyer. We will cover the cost if sending replacement/repaired items. Within 7 days after receiving your products, we offers a no-hassle 7 day exchange/replace only if your items are found to be defective by manufacturer. Condition: Neu, Marke: Markenlos, Herstellernummer: nicht zutreffend, Herstellungsland und -region: China, Brand: Unbranded, MPN: Does not apply, Country/Region of Manufacture: China, Cooling condition: wind system+closed circulating+cooling system, type: Q-switch Nd, The pulse energy: 0~1000mJ, Pulse width: 6ms, Laser wavelength: 1064nm / 532nm/BD-LS, Recurrence rate: 1, 2, 3, 4, 5, 6Hz, Power input: 110v~220v, Power: 300W, Function: Tattoo/Eyebrow/Pigment Removal, Stecker: EU Stecker, EAN: Does not apply

PicClick Insights PicClick Exklusiv
  •  Popularität - 91 blicke, 0.9 views per day, 106 days on eBay. Hohe von blicke. 0 Verkauft, 2 Verfügbar.
  •  Preis -
  •  Verkäufer - 78.256+ artikel verkauft. 1.9% negativ bewertungen. Verkäufer mit Top-Bewertung! Schiffe pünktlich mit Tracking, 0 Probleme mit vergangenen Verkäufen.
Ähnliche Artikel Items