Brand | Fluke |
Model | 107 |
Precision specifications | ||||
AC voltage |
Range |
Resolution |
Accuracy | |
(40 Hz to 500 Hz) 1 |
6.000 V |
0.001 V |
1.0 % + 3 | |
|
60.00 V |
0.01 V | ||
|
600.0 V |
0.1 V | ||
DC voltage |
6.000 V |
0.001 V |
0.5 % + 3 | |
60.00 V |
0.01 V | |||
600.0 V |
0.1 V | |||
Exchange millivolts |
600.0 mV |
0.1 mV |
3.0 % + 3 | |
Diode test 2 |
2.000 V |
0.001 V |
10% | |
Resistance |
400.0 Ω |
0.1 Ω |
0.5 % + 3 | |
(ohm) |
4.000 kΩ |
0.001 kΩ |
0.5 % + 2 | |
|
40.00 kΩ |
0.01 kΩ |
0.5 % + 2 | |
|
400.0 kΩ |
0.1 kΩ |
0.5 % + 2 | |
|
4.000 MΩ |
0.001 MΩ |
0.5 % + 2 | |
|
40.00 MΩ |
0.01 MΩ |
1.5% + 3 | |
Capacitor 3 |
50.00 nF |
0.01 nF |
2 % + 5 | |
500.0 nF |
0.1 nF |
2 % + 5 | ||
5.000 μF |
0.001 μF |
5 % + 5 | ||
50.00 μF |
0.01 μF |
5 % + 5 | ||
500.0 μF |
0.1 μF |
5 % + 5 | ||
1000 μF |
1 μF |
5 % + 5 | ||
Frequency 4 Hz |
50.00 Hz |
0.01 Hz |
0.1 % + 3 | |
(10 Hz – 100 kHz) |
500.0 Hz |
0.1 Hz | ||
|
5.000 kHz |
0.001 kHz | ||
|
50.00 kHz |
0.01 kHz | ||
|
100.0 kHz |
0.1 kHz | ||
Duty cycle 4 |
1 % to 99 % |
0.10% |
1 % typical case 5 | |
AC current |
4.000 A |
0.001 A |
1.5 % + 3 | |
(40 Hz - 200 Hz) |
10.00 A |
0.01 A | ||
DC |
4.000 A |
0.001 A |
1.5 % + 3 | |
10.00 A |
0.01 A | |||
1. All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified. | ||||
2. Typically, the open circuit test voltage is 2.0 V and the short circuit current is < 0.6 mA. | ||||
3. The parameters do not include errors due to test lead capacitance and capacitor substrate (up to 1.5 nF in the 50 nF range). | ||||
4. All AC current, frequency, and duty cycle are specified from 1% to 100% of the range. Input values below 1% of range are not specified. | ||||
5. Typically, the frequency is 50 Hz or 60 Hz and the duty cycle is 10% to 90%. | ||||
| ||||
Features |
Overload protection |
Input impedance (nominal value) |
Common mode rejection ratio |
Normal mode rejection ratio |
AC voltage |
600 V 1 |
>10 MΩ <100 pF 2 |
>60 dB at 50 Hz or 60 Hz at DC current |
− |
Exchange millivolts |
600 mV |
>1M, <100 pF |
>80 dB at 50 Hz or 60 Hz |
− |
DC voltage |
600 V 1 |
>10 MΩ <100 pF |
>100 dB at 50 Hz or 60 Hz at DC current |
>60 dB at 50 Hz or 60 Hz |
1. Up to 6 x 105 V Hz | ||||
2. For medium voltage (alternating current), the input impedance is approximately 1 MΩ. | ||||
| ||||
General technical indicators | ||||
The highest voltage applied to any terminal and ground |
600 V | |||
Display (LCD) |
6000 counts, updated three times per second | |||
Type of battery |
Two AAA batteries (NEDA 24A, IEC LR03) | |||
Battery life |
At least 200 hours | |||
Temperature | ||||
Operating temperature |
0 °C to 40 °C | |||
Storage temperature |
-30 °C to 60 °C | |||
Relative humidity | ||||
Working humidity |
No condensation below 10 °C | |||
≤ 90 % at 10 °C to 30 °C; ≤ 75 % at 30 °C to 40 °C | ||||
Working humidity, 40 MΩ range |
≤ 80 % at 10 °C to 30 °C; ≤ 70 % at 30 °C to 40 °C | |||
Altitude | ||||
Working elevation |
2000 m | |||
Storage altitude |
12,000 m | |||
Temperature coefficient |
0.1 X (specified accuracy) / °C (<18 °C or >28 °C) | |||
Current input fuse protection |
11A, 1000V fast-melting type, must use Fluke designated parts | |||
Volume (height x width x length) |
142 mm x 69 mm x 28 mm | |||
Weight |
200 g | |||
Protection level |
IEC 60529: IP 40 | |||
Safety |
IEC 61010-1: 600 V CAT III, pollution degree 2 | |||
Electromagnetic environment |
IEC 61326-1: Portable |
The product comes with the Indian Plug type, you have to use the International adapter with the plug.
It will be appreciated that you can leave us a positive feedback, if you are satisfied with our products and services.